Failure diagnostics that tell you why your site is down.

Every failed check records the phase that failed, the timing, the address we connected to, the response your server sent and the regions that saw it. You are alerted only when an outage is confirmed, so the detail you open is about a real failure.

Early access. We will email you when there is a place for you.

An alert that says a check failed leaves the real work to you.

Was it DNS? Could we connect? Did the handshake fail, or did your application answer with an error? Those are different problems with different owners, and most monitors report all of them as down.

We write the answer down at the moment of the failure, so it is waiting when you follow the link in the alert.

Start with the layer the problem is in.

Each check is timed in phases, and a failure records the phase it stopped at with a plain description of what went wrong.

For websites and APIs the phases are the DNS lookup, the connection, the TLS handshake and the time to first byte. For mail servers they are the DNS lookup, the connection and the TLS handshake.

Four failures that look identical in an ordinary alert look nothing alike here. You know where to look before you open a terminal.

See which server we reached, and who saw it fail.

Each result records the addresses the name resolved to, the address we connected to and the region that ran the check.

When one of four servers behind a name is broken, the connected address tells you which one. When one region fails and another passes, you know to look at the network path before the server.

A Down period lists every region that saw it, so you can tell an outage everyone can see from a problem in one part of the world.

Read what your server actually said.

When an HTTP check gets a response that fails, we keep the response headers and the start of the body. The error your server sent is often the whole answer.

That includes a healthy status with the wrong content. If you expect a keyword and the page comes back without it, the check fails and the snippet shows what was served.

HTML is reduced to readable text, so you see the message and not the markup. Header values that look sensitive, such as cookies and tokens, are redacted before anything is stored.

Follow every change of state, with how long it lasted.

Each check has a timeline of when it was Up, Degraded or Down and for how long. A Down period carries the regions that saw it, the error and the phase timing from the check that started it.

Blips are counted against the period they happened in, so a check that is Up and shaky looks different from one that is Up and quiet.

Results are kept for 90 days, with uptime figures for the last 24 hours and the last 30 days.

False alarms are kept out before anyone is emailed.

One failed request from one location is not an outage. When a check fails in one region, another region rechecks it within seconds. Only a confirmed failure marks the check Down.

If the recheck passes, we record a blip and the check stays Up. If one region keeps failing while another keeps passing, the check is Degraded, and you can see that in the dashboard without being woken for it.

A check pinned to a single region is not rechecked from anywhere else.

  • London failed San Francisco passed

    UpA blip. We record it and count it, and nobody is emailed.

  • London keeps failing San Francisco keeps passing

    DegradedOne region cannot reach you and another can. You see it in the dashboard.

  • London failed San Francisco failed

    DownConfirmed from another region. This is the one that can reach your inbox.

Consecutive failures

Choose how many confirmed failures an outage needs before you are alerted. It is set per check.

Minimum outage time

Choose how long a check must have been Down first, so a short outage that fixes itself stays out of your inbox.

Cooldown

You get one email when the outage is confirmed, not one per failed check. If it is still down when the cooldown ends, 60 minutes by default, the alert repeats.

Recovery

When the check passes again you get a recovery email that says how long the outage lasted.

[DOWN] API is failing

API is down.

Check: API
Status: FAILING
Response Time: 212ms
Description: status 502

View: a link to the check

[UP] API has recovered after 7m 12s

API has recovered.

Check: API
Status: RECOVERED
Downtime: 7m 12s
Response Time: 184ms

View: a link to the check

The email carries the description and a link. The phase timing, addresses and captured response are in the dashboard behind the link, and your AI agent can read them too.

We run it on our own production.

Uptime Champion watches CloudMailin around the clock, across dozens of checks. False alarms and alerts with no detail were two of the reasons we built it.

Our own website check expects a phrase from the page as well as a successful status. A deploy that serves the wrong page with a healthy status still fails, and the captured snippet shows what was served.

Our own alerts wait for several confirmed failures before they send. When one arrives, we open the check and read the phase before we open anything else.

Questions about outages and false alarms.

Why does my monitor say my site is down when it works for me?

Usually because the path between one monitoring location and your server had a problem that your own connection did not. We recheck a failure from another region within seconds before treating it as an outage.

A failure that only one region sees is recorded as a blip, and nobody is emailed.

How do I find out why my website went down?

Start with the phase that failed. A DNS failure, a refused connection, a TLS failure and an error from the application have different causes and different owners.

Each failed check records which one it was, the timing up to that point, the address we connected to and, for HTTP checks, the response your server sent.

What do Up, Degraded and Down mean?

Up means checks are passing. Down means a failure was confirmed: another region failed too, or nothing passed within the confirmation window.

Degraded means one region has failed three checks in a row while another region kept passing.

What is captured when an HTTP check fails?

Up to 50 response headers and roughly the first 2 KB of the body as text. HTML is reduced to readable text, and binary responses are not stored.

A response is captured only when the server sent one. A timeout or a refused connection has phase and address detail and no response.

Are secrets in a captured response stored?

Header names are kept and sensitive values are redacted. That covers cookies, authentication headers and any header whose name suggests a token, key, password or session.

The body snippet is stored as your server sent it, so avoid pointing a check at a page that prints secrets in its error output.

Does the alert email include the diagnostics?

No. The email has the check name, the error description, the response time and a link. The phase timing, addresses and captured response are in the dashboard behind that link, and your AI agent can read them too.

Start with the answer.

Join the waitlist for early access, and tell us what you would monitor.

Early access. We will email you when there is a place for you.